Applications
Standards
Comply with Standard YD/T 1258.2, ICEA-596, GR-409, IEC 60794-2-10/11, etc; and PVC cable meet the requirements of UL approval OFNR and OFNP; Different LSZH jacket meet IEC 60332-1 or IEC 60332-3Cor OFNR certification.
Technical Parameters
Cable Code |
Cable Diameter mm |
Cable Weight(Ref) kg/km |
TBF Diameter µm |
Tensile Strength Long /Short term N |
Crush Resistance Long/Short term N/100mm |
Bending Radius Dynamic/Static mm |
|
PVC Jacket |
LSZH Jacket |
||||||
SXC-1.6 |
1.6 ± 0.2 |
2.4 |
2.6 |
600 ± 50 |
40/80 |
100/500 |
60/30 |
SXC-1.9 |
1.9 ± 0.2 |
3.5 |
4.5 |
900 ± 50 |
60/100 |
100/500 |
60/30 |
SXC-2.8 |
2.8 ± 0.2 |
6.0 |
7.5 |
900 ± 50 |
60/100 |
100/500 |
60/30 |
Optical Characteristics
Fiber |
Attenuation |
Overfilled Modal Bandwidth (OFL BW) |
Effective Modal Bandwidth |
10Gb/s Ethernet link distance SX |
Min. Bending Radius |
|||
Wavelength |
1310/1550nm |
850/1300nm |
850/1300nm |
850nm |
850nm |
/ |
||
Typical |
Max. |
Typical |
Max. |
|||||
Unit |
dB/km |
dB/km |
dB/km |
dB/km |
MHZ.km |
MHZ.km |
m |
mm |
G652D |
0.36/0.22 |
0.5/0.4 |
--- |
--- |
--- |
--- |
--- |
16 |
G657A1 |
0.36/0.22 |
0.5/0.4 |
--- |
--- |
--- |
--- |
--- |
10 |
G657A2 |
0.36/0.22 |
0.5/0.4 |
--- |
--- |
--- |
--- |
--- |
7.5 |
50/125 |
--- |
--- |
3.0/1.0 |
3.5/1.5 |
≥500/500 |
--- |
--- |
30 |
62.5/125 |
--- |
--- |
3.0/1.0 |
3.5/1.5 |
≥200/500 |
--- |
--- |
30 |
OM3 |
--- |
--- |
3.0/1.0 |
3.5/1.5 |
≥1500/500 |
≥2000 |
≤300 |
30 |
OM4 |
--- |
--- |
3.0/1.0 |
3.5/1.5 |
≥3500/500 |
≥4700 |
≤550 |
30 |
BI-OM3 |
--- |
--- |
3.0/1.0 |
3.5/1.5 |
≥1500/500 |
≥2000 |
≤300 |
7.5 |
BI-OM4 |
--- |
--- |
3.0/1.0 |
3.5/1.5 |
≥3500/500 |
≥4700 |
≤550 |
7.5 |
Transport/ Storage/ Operating Temperature: -40℃~+70℃, Installation Temperature: -40℃~+70℃